BHA-3000 Automatic Hematology Analyzer is employed to count red blood cells, white blood cells, and platelets in blood samples. The results can be used to measure the hemoglobin and calculate relevant parameters of blood cells. It is applicable in hospitals, clinics, and laboratories.

  • Sample Type:

    Whole Blood (Venous/Capillary), Pre-dilution
  • Methodology:

    Electrical impedance method and colorimetry
  • Reaction time:

    60 samples/hour
  • Dimensions:

    328 mm x 425 mm x 446 mm (L x Wx H)
  • Weight:

    16 kg

BHA-3000

Automatic Hematology Analyzer

 


 

Intended Use

BHA-3000 Automatic Hematology Analyzer is employed to count red blood cells, white blood cells, and platelets in blood samples, and colorimetry is adopted to measure the hemoglobin and calculate relevant parameters of blood cells.

 

Features

 Optimized Liquid System 

Extremely Low Failure Rate & Excellent Maintainability

 

 Linear Fitting 

Break the 2 fL Limit of Detection of Platelet Volume

 

 Intelligent Floating Threshold 

Accurate Classification & Reliable Result

 

No Residue

  • No Residue of Hematology Diluent or Lysing Reagent
  • High Cost Performance

 

 Small Blood Sample 

  • Venous Blood: 6 μL
  • Capillary Blood (pre-dilution mode): 20 μL

 

 

Specifications

Product Name

BHA-3000 Automatic Hematology Analyzer

Parameters

Abnormal Sample Alarm
3-part WBC Differential
21 Reportable Parameters
3 Histograms

Type

Blood Analysis System

Display

10.4 Inch Resistive Screen

Certificate

CE, NMPA

Application

Hospital, Clinic, Laboratory

Reagent Type

Two Reagents: 1 Diluent and 1 Lyse

Sample Mode

Whole Blood (Venous/Capillary), Pre-dilution

Dimension

328mm*425mm*446mm (L*W*H)

Weight

16 KG

Working Environment

18~30℃

≤80% Relative Humidity
75 kPa~106 kPa

 

Test Items 

 

White Blood Cell

WBC

Mean Corpuscular Hemoglobin Concentration

MCHC

Neutrophil#

NEU#

Mean Corpuscular Hemoglobin

MCH

lntermediate Cell#

MXD#

Red Cell Volume Distribution Width-Standard Deviation

RDW-SD

Lymphocyte#

LYM#

Red Blood Cell Specific Volume

HCT

Neutrophil%

NEU%

Platelet

PLT

lntermediate Cell%

MXD%

Mean Platelet Volume

MPV

Lymphocyte%

LYM%

Platelet Distribution Width

PDW

Red Blood Cell

RBC

Plateletcrit

PCT

Hemoglobin (Concentration)

HGB

Platelet-Large Cell Ratio

P-LCR

Mean Cell Volume

MCV

Platelet-Large Cell Count

P-LCC

              Red Cell Volume Distribution Width-Coefficient of Variation

RDW-CV

 

 
 
Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • Blood Testing Device
Submit
Related Products
ASO Rheumatism Fast Test Kit ASO Rheumatism Fast Test Kit
ASO Fast Test Kit (Immunofluorescence Assay)
>ASO Fast Test Kit  (Immunofluorescence Assay)   Intended Use ASO Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of anti streptolysin "O" antibody (ASO) in serum, plasma or whole blood samples. ASO is a very valuable marker for the diagnosis of group A streptococcal infection, its titer can reflect the severity of infection. Some diseases will lead to a significant increase in ASO titer, such as wind damp heat, acute glomerulonephritis, nodular erythema, scarlet fever, acute tonsillitis.   About ASO Streptolysin "O", a protein with hemolytic activity, is one of the important metabolites of group A streptococcus. It can dissolve the red blood cells of human and some animals. Streptolysin "O" has strong antigenicity. When human is infected with group A hemolytic streptococcus, B lymphocytes will secrete corresponding antibodies under the stimulation of streptolysin "O", that is, anti streptolysin "O" (ASO). This antibody can neutralize streptolysin "O" and disable its hemolytic ability. ASO began to rise one week after group A Streptococcus infection, peaked in 4-5 weeks and lasted for several months.As the infection subsides, ASO decreased and returned to normal value within 6 months. The disease condition can be judged by repeated measurements over time. The increase of ASO over time indicates the early stage of infection, decrease indicates the subside stage of infection. The lack of decline in ASO titer suggested the possibility of recurrent or chronic infection.   Specification   Test Item Sample Type Method Storage Condition ASO S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 60.0-1370.0 IU/mL 10 min 400.0 IU/mL 24 months   Applicable Device   Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer    
Chemiluminescence Immunoassay Analyzer Chemiluminescence Immunoassay Analyzer
MAGICL 6200 Chemiluminescence Analyzer
>The MAGICL 6200, a high-speed, innovative chemiluminescence immunoassay analyzer, is perfect for medium to high process laboratories requiring a one-step chemiluminescence solution. The instrument is highly efficient and space-saving, with optional automatic centrifuge and decapper module, and a three-track design to meet emergency needs.
Fully Automated Clinical Chemistry Analyzer Fully Automated Clinical Chemistry Analyzer
CM-800 Clinical Chemistry Analyzer
>CM-800 Clinical Chemistry Analyzer   Intended Use CM-800 is a fully automated analyzer intended for the quantitative analysis of chemical components in human serum, plasma, whole blood, urine, and cerebrospinal liquid samples.    Constant processing speed:800 T/h Reagent capacity: 114 Sample capacity: 137 Minimum sample volume: 1.5 μL Minimum reaction volume: 100 μL         Technical Specifications   Principle Latex Immunoturbidimetry, Immunoturbidimetry, Colorimetry Method Rate method, End point method, Fixed time method Throughput Constant speed 800T/h Optional ISE module 200T/h Sample Tray 137 sample positions (including patient samples, calibrators and controls)  Reagent Tray Reagent positions: 69 positions for outside track and 45 for inside track Minimum Reaction Volume 100μL Cuvette Quartz glass 165 cuvettes, individually replaceable Reaction Temperature Direct solid heating, (37±0.2) ℃ constant temperature control Instrument Water Consumption 20 L purified water per hour Dimensions 1640mm(L)× 940mm(W) × 1215mm(H) Weight 500 kg   Test Items       Liver Function TBA, AFU, ALT, AST, ALP, AMM, GGT, TP, GPDA, GLDH, ALB, TB, DB, PA, CHE, ADA, 5’-NT, LAP, MAO, CG, GR Renal Function CRE-E, Urea, UA, β2-MG, CYS-C, MALB, NAG, RBP, CSF Specific Protein and Rheumatism ASO, RF, CRP, fCRP, Fer, CCP, Hs-CRP, TRF, RBP, C3, C4, IgA, IgM, IgG Glycometabolism GLU-HK, GLU-OX, FMN, D3-H, HbA1c, GA, LAC, NEFA Blood Lipids and Cardiovascular TG, TCH, HDL-C, LDL-C, ApoA1, ApoB, ApoE, Lp(a), HCY, NEFA, ACE, Myo, Lp-PLA2 Pancreatitis LPS, AMY Venous Thromboembolism and Coagulation D-Dimer Trace Elements and Electrolytes Ca, Mg, P, CO2, Fe, Na, Cl, K, UIBC Myocardial Enzyme CK, CK-MB, CK-MB mass, LDH, HBDH, LDH1 Tumor SA, AFU, Fer, TRF Gastric Function PG Ⅰ, PG Ⅱ
CK-MB/cTnI Quantitative POC Test Kit CK-MB/cTnI Quantitative POC Test Kit
CK-MB/cTnI Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB/cTnI Fast Test Kit  is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
Multiple Channel Portable POCT Analyzer Multiple Channel Portable POCT Analyzer
Getein 1180 Immunofluorescence Quantitative Analyzer
>Getein 1180 Immunofluorescence Quantitative Analyzer is used to measure the concentration of biomarkers in human whole blood, serum, plasma, urine, nasal swab, or saliva samples. 
Portable Veterinary POC analyzer Portable Veterinary POC analyzer
Getein 1100 Vet lmmunofluorescence Quantitative Analyzer
>Getein 1100 Vet is a compact and semi-automated POCT analyzer that can be used as an aid in clinical diagnostics for pets.
Cardiopulmonary Diagnosis and Rehabilitation Solution Cardiopulmonary Diagnosis and Rehabilitation Solution
One-stop Diagnosis + Cardiopulmonary Rehabilitation Solution
>Cardiopulmonary Rehabilitation can improve cardiac and systemic dysfunction caused by cardiovascular diseases, solve residual disease problems after acute and severe diseases, prevent recurrence of cardiovascular events, and help patients return to a healthy life.
Leading SARS-CoV-2 Neutralizing Antibody Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading SARS-CoV-2 Neutralizing Antibody Fast Test Kit (Immunofluorescence Assay) Manufacturer
SARS-CoV-2 Neutralizing Antibody Fast Test Kit (Immunofluorescence Assay)
>Getein SARS-CoV-2 Neutralizing Antibody Fast Test Kit (Immunofluorescence Assay) is used as an aid in identifying individuals with an adaptive immune response to SARS-CoV-2, indicating recent or prior infection, it should not be used to diagnose acute SARS-CoV-2 infection.  
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service