Contact Getein
Products
cTnI Troponin I Rapid Test Kit Colloidal Gold
cTnI Troponin I Rapid Test Kit Colloidal Gold

Cardiac Troponin l Fast Test Kit (Colloidal Gold)

Getein Cardiac Troponin l Fast Test Kit (Colloidal Gold) is intended for in vitro qualitative and semi-quantitative determination of cardiac Troponin l (cTnl) in serum, plasma or whole blood.
  • Test Item:

    Cardiac Troponin l
  • Sample Type:

    Serum, Plasma or Whole Blood
  • Test Time:

    15 min
  • Methodology:

    Colloidal Gold

Cardiac Troponin l Fast Test Kit

(Colloidal Gold)

 


 

Intended Use

Cardiac Troponin l Fast Test Kit is intended for in vitro qualitative and semi-quantitative determination of cardiac Troponin l (cTnl) in serum, plasma or whole blood. This test is used as an aid in the diagnosis of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).

 

About cTnl

Clinical studies have demonstrated the release of cTnl into the blood stream within hours following acute myocardial infarctions (AMI) or ischemic damage. Elevated levels of cTnl are detectable in blood within 4 to 6 hours after the onset of chest pain, reaching a peak in approximately 8 to 28 hours, and remaining elevated for 3 to 10 days following AMI. Due to the high myocardial specificity and the long duration of elevation, cTnl has become an important marker in the diagnosis and evaluation of patients suspected of AMI.

 

Specifications

Product Name

Test Item

 Test Samples

Storage Condition

Cardiac Troponin l Fast Test Kit

 

cTnI

 

S/P/WB

4-30℃

Methodology

Test Time

Cut-off Value

Shelf Life

Colloidal Gold

15 min

0.3 ng /mL

24 months

 

 

Clinical Application

1. As an aid in the early diagnosis of acute myocardial infarction (AMI).

2. Acute myocarditis, unstable angina, acute coronary syndrome (ACS).

3. Evaluate the severity of myocardial damage.

4. As an aid in the prognosis of ACS.

 

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • cTnI Troponin I Rapid Test Kit Colloidal Gold
Submit
Related Products
Leading One Step Test for D-Dimer (Colloidal Gold) Manufacturer Leading One Step Test for D-Dimer (Colloidal Gold) Manufacturer
One Step Test for D-Dimer (Colloidal Gold)
>Getein One Step Test for D-Dimer (Colloidal Gold) is used as an aid in the assessment and exclusion of suspected deep vein thrombosis (DVT) or pulmonary embolism (PE) in the Physical Department or emergency room (ER).
Multiple Channel Portable POCT Analyzer for Vet Multiple Channel Portable POCT Analyzer for Vet
Getein 1160 Vet Immunofluorescence Quantitative Analyzer
>Getein 1160 is a multi-channel analyzer which has 4 incubation channels and 1 emergency test channel, and also has constant test environment with 32℃ to ensure more accurate test results for your loving pets.
H-FABP Quantitative POC Fast Test Kit H-FABP Quantitative POC Fast Test Kit
H-FABP Fast Test Kit (Immunofluorescence Assay)
>Getein H-FABP Fast Test Kit is used in the early diagnosis of AMI and pulmonary embolism, and monitoring of chronic heart failure.
Compact Blood Coagulation Analyzer Compact Blood Coagulation Analyzer
Semi-Automated Blood Coagulation Analyzer XN 06
>XN 06 is a compatible, easy-to-operate, four-channel, semi-automated coagulation analyzer. Utilizing photometric method, the device is intended for testing 4 routine clotting test items, which are PT, TT, APTT and FIB.
Automatic Clinical Chemistry Analyzer Automatic Clinical Chemistry Analyzer
BBA-300 Automatic Clinical Chemistry Analyzer
>BBA-300 Automatic Clinical Chemistry Analyzer     “No-Wait” Emergency Test Mode  No need of pausing the testing procedure, emergency samples are given test priority and can be tested at any time during analysis. Stable & reliable clinical chemistry test   Highly-Efficient and Convenient Test  Constant test speed of 300 T/h Emergency samples in test priority at any time LIS bi-directional connectivity Automatic test report printing    Multifunctional and Precise Sample Probe  Highly-polished probe Automatic inside and outside probe washing, reducing cross contamination Highly sensitive liquid level detection sensor Actively monitoring reagent volume Protection of probe collision Auto adjustment of sampling depth of sample probe    Sample and Reagent Unit  45 sample positions 90 reagent positions Built-in refrigeration system, continual 24-hour on-board cooling Built-in barcode reader for reagents and samples (optional item)    Reaction Unit  120 cuvettes, can be replaced separately The cuvettes are made of new-type non-crystalline optical plastic with better light transmittance Minimum reaction volume: 150 μL Stable and precise temperature control (37.0 ± 0.2°C) 5-step cuvette Wash Station, thorough cleaning    Stirring Unit  Independent stirring paddle lmported Teflon coating technology Effectively preventing cross contamination    Advanced Operation System  lntuitive user-friendly interface, easy to learn and use Auto sample dilution Auto stopping and warning when reagents or samples run out Calibration with linear or non-linear curves. Multi-point calibration Automatically detecting cuvettes status and screening flawed cuvettes   Technical Parameters   Test Principles Turbidimetry, colorimetry Test Methods End-point method, Rate method, two-point method Test Speed Constant speed of 300 T/h Sample Types Blood, urine, hydrothorax, cerebrospinal fluid Reaction Temperature 37.0 ± 0.2°C (constant temperature) Dimensions Floor-standing: 1060 mm × 660 mm × 1230 mm Benchtop: 1060 mm × 660 mm × 540 mm Weight Floor-standing: 140 kg Benchtop: 85 kg     Floor-standing Benchtop   Test Item     Liver Function TBA, AFU, ALT, AST, ALP, AMM, GGT, TP, GPDA, GLDH, ALB, TB, DB, PA, CHE, ADA, 5’-NT, LAP, MAO, CG, GR Renal Function CRE-E, Urea, UA, β2-MG, CYS-C, MALB, NAG, RBP, CSF Specific Protein and Rheumatism ASO, RF, CRP,  Fer, CCP, Hs-CRP, TRF, RBP, C3, C4, IgA, IgM, IgG Glycometabolism GLU-HK, GLU-OX, FMN, D3-H, HbA1c, GA, LAC, NEFA Blood Lipids and Cardiovascular TG, TCH, HDL-C, LDL-C, ApoA1, ApoB, ApoE, Lp(a), HCY, NEFA, ACE, Myo, Lp-PLA2 Pancreatitis LPS, AMY Venous Thromboembolism and Coagulation D-Dimer Trace Elements and Electrolytes Ca, Mg, P, CO2, Fe, Na, Cl, K, UIBC Myocardial Enzyme CK, CK-MB, CK-MB mass, LDH, HBDH, LDH1 Tumor SA, AFU, Fer, TRF Gastric Function PG Ⅰ, PG Ⅱ      
Getein NGAL Quantitative POC Fast Test Kit Getein NGAL Quantitative POC Fast Test Kit
NGAL Fast Test Kit (Immunofluorescence Assay)
>Getein NGAL Fast Test Kit is used as an aid in the early diagnosis of acute kidney injury (AKI), risk classification and treatment monitoring.
ASO Rheumatism Fast Test Kit ASO Rheumatism Fast Test Kit
ASO Fast Test Kit (Immunofluorescence Assay)
>ASO Fast Test Kit  (Immunofluorescence Assay)   Intended Use ASO Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of anti streptolysin "O" antibody (ASO) in serum, plasma or whole blood samples. ASO is a very valuable marker for the diagnosis of group A streptococcal infection, its titer can reflect the severity of infection. Some diseases will lead to a significant increase in ASO titer, such as wind damp heat, acute glomerulonephritis, nodular erythema, scarlet fever, acute tonsillitis.   About ASO Streptolysin "O", a protein with hemolytic activity, is one of the important metabolites of group A streptococcus. It can dissolve the red blood cells of human and some animals. Streptolysin "O" has strong antigenicity. When human is infected with group A hemolytic streptococcus, B lymphocytes will secrete corresponding antibodies under the stimulation of streptolysin "O", that is, anti streptolysin "O" (ASO). This antibody can neutralize streptolysin "O" and disable its hemolytic ability. ASO began to rise one week after group A Streptococcus infection, peaked in 4-5 weeks and lasted for several months.As the infection subsides, ASO decreased and returned to normal value within 6 months. The disease condition can be judged by repeated measurements over time. The increase of ASO over time indicates the early stage of infection, decrease indicates the subside stage of infection. The lack of decline in ASO titer suggested the possibility of recurrent or chronic infection.   Specification   Test Item Sample Type Method Storage Condition ASO S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 60.0-1370.0 IU/mL 10 min 400.0 IU/mL 24 months   Applicable Device   Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer    
Leading Prog Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading Prog Fast Test Kit (Immunofluorescence Assay) Manufacturer
Prog Fast Test Kit (Immunofluorescence Assay)
>Getein Prog Fast Test Kit is used to measure ovarian function and can determine if a woman has ovulated and when the ovulation occurred.
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service