Contact Getein
Products
fT4 Fast Test Kit (Immunofluorescence Assay)
fT4 Fast Test Kit (Immunofluorescence Assay)

fT4 Fast Test Kit (Immunofluorescence Assay)

Getein fT4 Fast Test Kit is used as an aid in the assessment of the thyroid status.

  • Test Item:

    fT4
  • Sample Type:

    Serum/Plasma/Whole Blood
  • Test Time:

    15 min
  • Methodology:

    Immunofluorescence Assay

fT4 Fast Test Kit

(Immunofluorescence Assay)

 

 


 

Intended Use

fT4 Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of free T4 in human serum, plasma and whole blood. This test can be used as an aid in the assessment of the thyroid status.

 

About fT4

Thyroxine (T4) is the main thyroid hormone secreted into the bloodstream by the thyroid gland. Together with triiodothyronine (T3), it plays a vital role in regulating the body's metabolic rate, influences the cardiovascular system, growth and bone metabolism, and is important for normal development of gonadal functions and nervous system.

T4 circulates in the bloodstream as an equilibrium mixture of free and serum bound hormone. Free T4 (fT4) is the unbound and biologically active form, which represents only 0.03 % of the total T4. The remaining T4 is inactive and bound to serum proteins such as thyroxine binding globulin (TBG,75%), pre-albumin (15%), and albumin (10%). The determination of free T4 has the advantage of being independent of changes in the concentrations and binding properties of these binding proteins; additional determination of a binding parameter (T uptake, TBG) is therefore unnecessary. Therefore, free T4 is a useful tool in clinical routine diagnostics for the assessment of the thyroid status.

 

Contents

1. For Getein1100/ Getein1180

Package specifications: 25 tests/box, 10 tests/box

1) Getein fT4 test card in a sealed pouch with desiccant

2) Disposable pipet

3) Sample diluent 1

4) User manual: 1 piece/box

5) SD card: 1 piece/box

2. For Getein1600:

Package specifications: 2×24 tests/box, 2×48 tests/box

1) Sealed cartridge with 24/48 Getein fT4 test cards

2) User manual: 1 piece/box

Materials required for Getein1600:

1) Sample diluent: 1 bottle/box

2) Box with pipette tips: 96 tips/box

3) Mixing plate: 1 piece/box

Note: Do not mix or interchange different batches of kits.

 

Specifications

Test Item

Sample

Method

Storage Condition

fT4

S/P/WB

Immunofluorescence

Assay

4-30℃

Detection Range

Test Time

Cut-off Value

Shelf Life

0.30-100.00 pmol/L

15 min

12.00-22.00 pmol/L

24 months

 

Applicable Device

Getein1100 Immunofluorescence Quantitative Analyzer

Getein1180 Immunofluorescence Quantitative Analyzer

Getein1600 Immunofluorescence Quantitative Analyzer

 

Clinical Application

1. As an aid in the assessment of the thyroid status.

2. lt should be measured together with TSH if thyroid disorders are suspected and is also suitable for monitoring thyrosuppressive therapy.

 

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • Leading fT4 Fast Test Kit (Immunofluorescence Assay) Manufacturer
Submit
Related Products
Leading TSH Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading TSH Fast Test Kit (Immunofluorescence Assay) Manufacturer
TSH Fast Test Kit (Immunofluorescence Assay)
>Getein TSH Fast Test Kit is used in the screening, clinical diagnosis, prognosis and therapeutic effect evaluation of thyroid diseases.    
Leading T3 Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading T3 Fast Test Kit (Immunofluorescence Assay) Manufacturer
T3 Fast Test Kit (Immunofluorescence Assay)
>Getein T3 Fast Test Kit is used in the monitoring of hyperthyroidism and hypothyroidism, and also used as an aid in the functional diagnosis of thyroidea.
Leading T4 Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading T4 Fast Test Kit (Immunofluorescence Assay) Manufacturer
T4 Fast Test Kit (Immunofluorescence Assay)
>Getein T4 Fast Test Kit is used in the monitoring of hyperthyroidism and hypothyroidism, and also used as an aid in the functional diagnosis of thyroidea.    
Leading fT3 Fast Test Kit (Immunofluorescence Assay) Manufacturer Leading fT3 Fast Test Kit (Immunofluorescence Assay) Manufacturer
fT3 Fast Test Kit (Immunofluorescence Assay)
>fT3 Fast Test Kit is used as an aid in clinical routine diagnostics for the assessment of the thyroid status.
NT-proBNP Quantitative POC Fast Test Kit NT-proBNP Quantitative POC Fast Test Kit
NT-proBNP Fast Test Kit (Immunofluorescence Assay)
>Getein NT-proBNP Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of Heart Failure (HF).
ASO Rheumatism Fast Test Kit ASO Rheumatism Fast Test Kit
ASO Fast Test Kit (Immunofluorescence Assay)
>ASO Fast Test Kit  (Immunofluorescence Assay)   Intended Use ASO Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of anti streptolysin "O" antibody (ASO) in serum, plasma or whole blood samples. ASO is a very valuable marker for the diagnosis of group A streptococcal infection, its titer can reflect the severity of infection. Some diseases will lead to a significant increase in ASO titer, such as wind damp heat, acute glomerulonephritis, nodular erythema, scarlet fever, acute tonsillitis.   About ASO Streptolysin "O", a protein with hemolytic activity, is one of the important metabolites of group A streptococcus. It can dissolve the red blood cells of human and some animals. Streptolysin "O" has strong antigenicity. When human is infected with group A hemolytic streptococcus, B lymphocytes will secrete corresponding antibodies under the stimulation of streptolysin "O", that is, anti streptolysin "O" (ASO). This antibody can neutralize streptolysin "O" and disable its hemolytic ability. ASO began to rise one week after group A Streptococcus infection, peaked in 4-5 weeks and lasted for several months.As the infection subsides, ASO decreased and returned to normal value within 6 months. The disease condition can be judged by repeated measurements over time. The increase of ASO over time indicates the early stage of infection, decrease indicates the subside stage of infection. The lack of decline in ASO titer suggested the possibility of recurrent or chronic infection.   Specification   Test Item Sample Type Method Storage Condition ASO S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 60.0-1370.0 IU/mL 10 min 400.0 IU/mL 24 months   Applicable Device   Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer    
Monkeypox Virus RT-PCR Detection Kit Monkeypox Virus RT-PCR Detection Kit
Monkeypox Virus Real-time PCR Kit
>Getein Monkeypox Virus Real-time PCR Kit is used for the qualitative detection of MPV in serum or lesion exudate samples.
Multiple Channel Portable POCT Analyzer Multiple Channel Portable POCT Analyzer
Getein 1160 Immunofluorescence Quantitative Analyzer
>Getein 1160 is a multi-channel analyzer which has 4 incubation channels and 1 emergency test channel, and also has constant test environment with 32℃ to ensure more accurate test results. 
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service