Contact Getein
Products
CK-MB Quantitative POC Test Kit
CK-MB Quantitative POC Test Kit

CK-MB Fast Test Kit (Immunofluorescence Assay)

Getein CK-MB Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).

 

 

  • Test Item:

    CK-MB
  • Sample Type:

    Plasma/Serum/Whole Blood
  • Test Time:

    10 min
  • Methodology:

    Immunofluorescence Assay

CK-MB Fast Test Kit 

(Immunofluorescence Assay)

 


 

Intended Use

CK-MB Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of CK-MB in human serum, plasma or whole blood samples. This test is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).

 

About CK-MB

Creatine kinases are dimer isozymes composed of two monomer subunits, CK-M (for skeletal muscle derived) and CK-B (for brain derived), which can form all three combinations of monomers: CK-BB, CK-MM, and CK-MB. BB is found primarily in the brain. Skeletal muscles primarily contain the MM isoform, with trace amount of MB (around 1-4% of total CK activity). Cardiac muscles also contain the MM isoform, but higher amount of MB, typically around 20% of total CK activity. CK-MB is a more sensitive marker of myocardial injury than total CK activity, because it has a lower basal level and a much narrower normal range. Medical literatures commonly state that CK-MB levels are elevated in 4 to 6 hours, peak at 10 to 24 hours, and return to normal within 3 to 4 days after an acute myocardial infarction. Classically, an increase of the myocardial-specific enzymeCK-MB is considered as the hallmark of acute myocardial infarction, and increased levels are frequently interpreted by the clinician as objective evidence of myocardial cell damage.

 

Specifications

 

Test Item

Sample

Detection Range

Storage Condition

CK-MB

P/S/WB

2.50-80.00 ng/mL

4-30℃

Method

Test Time

Cut-off Value

Shelf Life

Immunofluorescence

Assay

10 min

5.0 ng/mL

24 months

 

Applicable Device

Getein1100 Immunofluorescence Quantitative Analyzer

Getein1160 Immunofluorescence Quantitative Analyzer

Getein1180 Immunofluorescence Quantitative Analyzer

Getein1600 Immunofluorescence Quantitative Analyzer

Getein1200 Immunofluorescence Quantitative Analyzer

 

Clinical Application

As an aid in the early diagnosis and risk classification of acute myocardial infarction (AMI).

 

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.
  • CK-MB Quantitative POC Test Kit
Submit
Related Products
cTnI Quantitative POC Test Kit cTnI Quantitative POC Test Kit
Cardiac Troponin I Fast Test Kit (Immunofluorescence Assay)
>Getein Cardiac Troponin I Fast Test Kit is used as an aid in the diagnosis of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).      
hs-cTnI Quantitative POC Fast Test Kit hs-cTnI Quantitative POC Fast Test Kit
hs-cTnI Fast Test Kit (Immunofluorescence Assay)
>Getein hs-cTnI Fast Test Kit can be used as an aid in the diagnosis of myocardial infarction (MI).
BNP Quantitative POC Fast Test Kit BNP Quantitative POC Fast Test Kit
BNP Fast Test Kit (Immunofluorescence Assay)
>Getein BNP Fast Test Kit is used as an aid in the diagnosis of congestive heart failure and for the risk stratification of patients with acute coronary syndromes (ACS).
CK-MB/cTnI Quantitative POC Test Kit CK-MB/cTnI Quantitative POC Test Kit
CK-MB/cTnI Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB/cTnI Fast Test Kit  is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
CK-MB/cTnI/H-FABP Quantitative POC Test Kit CK-MB/cTnI/H-FABP Quantitative POC Test Kit
CK-MB/cTnI/H-FABP Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB/cTnI/H-FABP Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
CK-MB/cTnI/Myo Quantitative POC Test Kit CK-MB/cTnI/Myo Quantitative POC Test Kit
CK-MB/cTnI/Myo Fast Test Kit (Immunofluorescence Assay)
>Getein CK-MB/cTnI/Myo Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
H-FABP Quantitative POC Fast Test Kit H-FABP Quantitative POC Fast Test Kit
H-FABP Fast Test Kit (Immunofluorescence Assay)
>Getein H-FABP Fast Test Kit is used in the early diagnosis of AMI and pulmonary embolism, and monitoring of chronic heart failure.
NT-proBNP Quantitative POC Fast Test Kit NT-proBNP Quantitative POC Fast Test Kit
NT-proBNP Fast Test Kit (Immunofluorescence Assay)
>Getein NT-proBNP Fast Test Kit is used as an aid in the clinical diagnosis, prognosis and evaluation of Heart Failure (HF).
Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service