Contact Getein
Search
5 results found for "Hematology Analyzer"
  • Blood Testing Device
    Blood Testing Device
    BHA-3000 Automatic Hematology Analyzer
    Key Features No Residue No residue of hematology diluent or lysing reagent Cost-effective Small Blood Sample Venous blood: 6 μL Capillary blood (pre-dilution mode): 20 μL Intelligent Floating Threshold Accurate classification & reliable result Optimized Liquid System Limited failure rate & excellent maintainability Linear Fitting Break the 2 fL limit of detection of platelet volume Reportable Parameters WBC, NEU#, MXD#, LYM#, NEU%, MXD%, LYM%, RBC, HGB, MCV, RDW-CV, MCHC, MCH, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 6 μL; capillary blood (pre-dilution): 20 μL Principles: Classic electrical impedance method, photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 425 mm x 446 mm (L x W x H)  Weight:16 kg Power Supply: 220V~ 50 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Blood Testing Device
    Blood Testing Device
    BHA-5000 Automatic Hematology Analyzer
    Key Features Digital Filtering Effectively remove interference Small Blood Sample Venous blood: 15 μL Capillary blood (pre-dilution mode): 20 μL Double Channels WBC double channels 2D classification, faster and more accurate 50μm Hole Accurate test of blood cells with 50 μm gem hole Coincidence Calibration Enhance analytical capabilities Reportable Parameters WBC, LYM#, NEU#, MON#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 471 mm x 446 mm (L x W x H)  Weight: 21 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • 5-part Veterinary Automatic Hematology Analyzer
    5-part Veterinary Automatic Hematology Analyzer
    BHA-5000 Vet Automatic Hematology Analyzer
    Key Features Humanization Venous blood sample volume: 15 uL Less pain during blood collection Sample type: venous blood/capillary blood (pre-dilution mode) to meet different needs Technology Innovation Intelligent scatter classification technology Curve-fitting&floating threshold technique Advanced methods Laser Scattering Method: Obtain information on the size and internal composition of WBC and classify them Digital Filtering: Effectively remove interference from impurity signals Optical Method for BASO: Avoid errors caused by the partial overlap of basophil and leukocyte High Efficiency and No Residue 60 T/H No hematology diluent or lysis reagent residues Blood Cell Overlap Correction Technology Make accurate judgments when cells overlap through the well Multi-Segment counting Better exclude biased results and improve test accuracy Smallest Gem Hole The industry's smallest gem hole of 50 um Display 10.4" capacitive touch screen, improve the sensitivity of touch operation Support operation with rubber gloves Species of Animals Dog, cat, pig, horse, sheep, rabbit, camel, one self-programmed animal Technical Specifications 23 Whole Blood Reportable:WBC、LYM%、LYM#、NEU%、NEU#、MON%、MON#、EOS%、EOS#、BAS%、BAS#、RBC、HGB、HCT、MCV、MCH、MCHC、RDW-SD、RDW-CV、PLT、PDW、MPV、PCT Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: Laser Scatter in Flow Cytometry,Classic Electrical Impedance Method,Mature Photoelectric Colorimetry Power Supply:220V±22~AC,50±1 Hz,Larger voltage range can be supported by transformers Sample Volume:Whole blood: 15μL; Diluted blood: 20μL Dimensions:328 mm (L) x 471 mm (W) x 446 mm (H)   Performance:Parameter Precision (CV%),WBC ≤4.0,RBC ≤2.0,HGB ≤2.0,PLT (10^3/μL) ≤8.0,MCV ≤3 Display:10.4 Inch capacitive touch screen Quality Control:L-J QC, X-B QC Weight:21 kg  
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 600 Modular System
    Key Features Maximizing the potential of the laboratory Metis 600 modular system provides suitable solutions for immunofluorescence and hematology testing in low volume laboratories Standardization Improve laboratory efficiency through the highest level of automation Reliability Maximize reliable results with industry-leading instrument accuracy and service Rapid Accelerate turnaround time for high-volume sample testing and achieve new levels of rapid service Capacity The combination of Immunofluorescence and Hematology methodologies allows for a more comprehensive test items to be offered Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 67 cm x 70.5 cm x 57 cm Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test items: 25 reportable parameters Quality control method: L-J quality control, X-B quality control Storage capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers   Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 67.5 cm × 57 cm × 57.4 cm Weight: 43 kg Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 120 T/H Test items: 42 items in 11 fields Storage capacity: 100, 000 test results Storage capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping    
  • Automatic 5-part Hematology Analyzer
    Automatic 5-part Hematology Analyzer
    BHA-5100 Automatic Hematology Analyzer
    Key Features Advanced Automatic Level Autorotating blood collection tubes for barcode scanning Automatic sample mixing technology Automatic puncture sampling Exceeding Detection Technology Digital filter and linear regression Floating threshold technology for cell differentiation Display Screen ≥10.4 inch LCD display screen Able to display data and diagrams simultaneously User Friendly Minimize manual operations Bidirectional connectivity of LIS and HIS Supports external devices such as printers, keyboards, mouse and more Emergency Sample Position Available   Reportable Parameters WBC, Lym#, Neu#, Mon#, Eos#, Bas#, Lym%, Mon%, Neu%, Eos%, Bas%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT,  P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 705 mm×670 mm×570 mm (L x W x H) Weight: 30 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  

A total of 1 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service