Benefits where you need Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Dry clinical chemistry and immunofluorescence Supporting multiple test items Combo test, highly efficient Reliable Accuracy Good correlation with CLIA method 32℃ constant test environment Convenient Easy to operate, user friendly interface Benefits where you need ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 160 mm × 80 mm × 24 mm (D×W×H) Weight: 256 g Printer: Support for external Bluetooth thermal printer Connectivity: USB/Bluetooth/WIFI Calibration: SD Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Chinese Cases Storage: Over 10,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Highly Efficient & Accurate Advanced fluorescence immunoassay Multiple quality control Convenient Operation SD card calibration Continuous test for 3 hours with lithium battery Real-time and Rapid Test 3-15 min/test 5 sec/test for multiple tests User-friendly Interface Android system 7-inch touch screen Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Methodology: Fluorescence Immunochromatography Channels: Single channel Sample Types: Serum, plasma, whole blood, urine, feces, fingertip blood, nasal swab, saliva Detection Time: 3-15 minutes Calibration: RFID Card Calibration Printer: Built-in thermal printer, paper size 5735 mm Display: 7.0-inch LCD color capacitive touchscreen, resolution 1024600, supports touch and handwriting operations Dimensions: 261 mm (L) × 241 mm (W) × 115 mm (H) Net Weight: Main unit 2000g, power adapter 430g, lithium battery pack (optional) 300g Operating System: Android system Data Storage: Stores 10,000 results (reagent storage capacity of 100,000, but excessive storagemay cause the Android system to crash; timely data cleanup is recommended) Communication Input: One SD card (old) slot, two USB ports Communication Output: One RS232 serial port, one Ethernet port Languages: English, Chinese, Spanish, Portuguese Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Multiple channels High throughput, 8 channels available (7 test channels + 1 emergency test channel) Multiple test items can be tested at the same time, saving operation time Constant Temperature Providing steady test environment with more accurate test results Easy Operation Android system, touch screen lmmediate edit of sample and patients' info. Convenient for viewing test results SD card calibration, touch for recognition WIFI connection, easy for data transmission None Contamination Waste container is set in the equipment, avoiding medical contamination Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 409 mm × 344 mm × 193 mm (W × D × H) Weight: 9 kg Printer: Real-time auto-printing, support for external printer Display: 10.1'' LCD touch screen Connectivity: Ethernet port for LIS/HIS COM port for PC ;2 USB ports for software update and file copy Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Cases Storage: Over 100,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Portable Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Reliable Accuracy Good correlation with CLIA methodConvenientEasy to operate, user friendly interfaceAuto Cartridge Collection Automatically receive the used test cards when the test is finishedTechnical Specifications Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Printer: Built-in Thermal Printer, support for external printer Display: 10.1'' LCD touch screen Connectivity: Ethernet port for LIS/HIS COM port for PC ;2 USB ports for software update and file copy Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Repeatability: CV ≤ 2% within range [100, 15000] mV ; CV ≤ 10% within range [0, 100) mV
Getein Testosterone Fast Test Kit (Immunofluorescence Assay) tests are used to assist in the diagnosis of female polycystic ovary syndrome and male testosterone insufficiency.
Getein lnfluenza A/B Fast Test Kit (lmmunofluorescence Assay) is used as an aid in the differentiation of patients with suspected influenza A and influenza B virus infection in conjunction with clinical symptoms and result of other diagnostic methods.
Getein Anti-CCP Fast Test Kit is intended for in vitro quantitative determination of anti-CCP in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA).
ASO Fast Test Kit (Immunofluorescence Assay) Intended Use ASO Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of anti streptolysin "O" antibody (ASO) in serum, plasma or whole blood samples. ASO is a very valuable marker for the diagnosis of group A streptococcal infection, its titer can reflect the severity of infection. Some diseases will lead to a significant increase in ASO titer, such as wind damp heat, acute glomerulonephritis, nodular erythema, scarlet fever, acute tonsillitis. About ASO Streptolysin "O", a protein with hemolytic activity, is one of the important metabolites of group A streptococcus. It can dissolve the red blood cells of human and some animals. Streptolysin "O" has strong antigenicity. When human is infected with group A hemolytic streptococcus, B lymphocytes will secrete corresponding antibodies under the stimulation of streptolysin "O", that is, anti streptolysin "O" (ASO). This antibody can neutralize streptolysin "O" and disable its hemolytic ability. ASO began to rise one week after group A Streptococcus infection, peaked in 4-5 weeks and lasted for several months.As the infection subsides, ASO decreased and returned to normal value within 6 months. The disease condition can be judged by repeated measurements over time. The increase of ASO over time indicates the early stage of infection, decrease indicates the subside stage of infection. The lack of decline in ASO titer suggested the possibility of recurrent or chronic infection. Specification Test Item Sample Type Method Storage Condition ASO S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 60.0-1370.0 IU/mL 10 min 400.0 IU/mL 24 months Applicable Device Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer
RF Fast Test Kit (Immunofluorescence Assay) Intended Use RF Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of rheumatoid factor (RF) in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA). About RF Rheumatoid factor is an autoantibody targeting the Fc fragment of human or animal denatured IgG molecule. RF mainly includes four types of IgM, IgG, IgA and IgE. IgM is the main type of RF, and this test kit mainly detects this type. Specification Test Item Sample Type Method Storage Condition RF S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 10.0-640.0 IU/mL 10 min 15.9 IU/mL 24 months Applicable Device Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer
Getein Cardiac Troponin I Fast Test Kit is used as an aid in the diagnosis of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).
Benefits where you need Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Dry clinical chemistry and immunofluorescence Supporting multiple test items Combo test, highly efficient Reliable Accuracy Good correlation with CLIA method 32℃ constant test environment Convenient Easy to operate, user friendly interface Benefits where you need ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 160 mm × 80 mm × 24 mm (D×W×H) Weight: 256 g Printer: Support for external Bluetooth thermal printer Connectivity: USB/Bluetooth/WIFI Calibration: SD Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Chinese Cases Storage: Over 10,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Highly Efficient & Accurate Advanced fluorescence immunoassay Multiple quality control Convenient Operation SD card calibration Continuous test for 3 hours with lithium battery Real-time and Rapid Test 3-15 min/test 5 sec/test for multiple tests User-friendly Interface Android system 7-inch touch screen Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Methodology: Fluorescence Immunochromatography Channels: Single channel Sample Types: Serum, plasma, whole blood, urine, feces, fingertip blood, nasal swab, saliva Detection Time: 3-15 minutes Calibration: RFID Card Calibration Printer: Built-in thermal printer, paper size 5735 mm Display: 7.0-inch LCD color capacitive touchscreen, resolution 1024600, supports touch and handwriting operations Dimensions: 261 mm (L) × 241 mm (W) × 115 mm (H) Net Weight: Main unit 2000g, power adapter 430g, lithium battery pack (optional) 300g Operating System: Android system Data Storage: Stores 10,000 results (reagent storage capacity of 100,000, but excessive storagemay cause the Android system to crash; timely data cleanup is recommended) Communication Input: One SD card (old) slot, two USB ports Communication Output: One RS232 serial port, one Ethernet port Languages: English, Chinese, Spanish, Portuguese Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Multiple channels High throughput, 8 channels available (7 test channels + 1 emergency test channel) Multiple test items can be tested at the same time, saving operation time Constant Temperature Providing steady test environment with more accurate test results Easy Operation Android system, touch screen lmmediate edit of sample and patients' info. Convenient for viewing test results SD card calibration, touch for recognition WIFI connection, easy for data transmission None Contamination Waste container is set in the equipment, avoiding medical contamination Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 409 mm × 344 mm × 193 mm (W × D × H) Weight: 9 kg Printer: Real-time auto-printing, support for external printer Display: 10.1'' LCD touch screen Connectivity: Ethernet port for LIS/HIS COM port for PC ;2 USB ports for software update and file copy Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Cases Storage: Over 100,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV
Key Features Portable Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Instant Results Get results in 3-15 minutes Detection Performance Improved Reduced influence by temperature and improved detection accuracy Reliable Accuracy Good correlation with CLIA methodConvenientEasy to operate, user friendly interfaceAuto Cartridge Collection Automatically receive the used test cards when the test is finishedTechnical Specifications Application Scenarios ICU Laboratory Emergency Clinic Test Menu Technical Specifications Dimensions: 299 mm (W) × 276 mm (D)× 152 mm (H) Weight: 4 kg Printer: Built-in Thermal Printer, support for external printer Display: 10.1'' LCD touch screen Connectivity: Ethernet port for LIS/HIS COM port for PC ;2 USB ports for software update and file copy Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine, swab, saliva, stool Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Repeatability: CV ≤ 2% within range [100, 15000] mV ; CV ≤ 10% within range [0, 100) mV
Getein Testosterone Fast Test Kit (Immunofluorescence Assay) tests are used to assist in the diagnosis of female polycystic ovary syndrome and male testosterone insufficiency.
Getein lnfluenza A/B Fast Test Kit (lmmunofluorescence Assay) is used as an aid in the differentiation of patients with suspected influenza A and influenza B virus infection in conjunction with clinical symptoms and result of other diagnostic methods.
Getein Anti-CCP Fast Test Kit is intended for in vitro quantitative determination of anti-CCP in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA).
ASO Fast Test Kit (Immunofluorescence Assay) Intended Use ASO Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of anti streptolysin "O" antibody (ASO) in serum, plasma or whole blood samples. ASO is a very valuable marker for the diagnosis of group A streptococcal infection, its titer can reflect the severity of infection. Some diseases will lead to a significant increase in ASO titer, such as wind damp heat, acute glomerulonephritis, nodular erythema, scarlet fever, acute tonsillitis. About ASO Streptolysin "O", a protein with hemolytic activity, is one of the important metabolites of group A streptococcus. It can dissolve the red blood cells of human and some animals. Streptolysin "O" has strong antigenicity. When human is infected with group A hemolytic streptococcus, B lymphocytes will secrete corresponding antibodies under the stimulation of streptolysin "O", that is, anti streptolysin "O" (ASO). This antibody can neutralize streptolysin "O" and disable its hemolytic ability. ASO began to rise one week after group A Streptococcus infection, peaked in 4-5 weeks and lasted for several months.As the infection subsides, ASO decreased and returned to normal value within 6 months. The disease condition can be judged by repeated measurements over time. The increase of ASO over time indicates the early stage of infection, decrease indicates the subside stage of infection. The lack of decline in ASO titer suggested the possibility of recurrent or chronic infection. Specification Test Item Sample Type Method Storage Condition ASO S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 60.0-1370.0 IU/mL 10 min 400.0 IU/mL 24 months Applicable Device Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer
RF Fast Test Kit (Immunofluorescence Assay) Intended Use RF Fast Test Kit (Immunofluorescence Assay) is intended for in vitro quantitative determination of rheumatoid factor (RF) in serum, plasma or whole blood samples. The test is designed to aid in the diagnosis of autoimmune diseases, such as rheumatoid arthritis (RA). About RF Rheumatoid factor is an autoantibody targeting the Fc fragment of human or animal denatured IgG molecule. RF mainly includes four types of IgM, IgG, IgA and IgE. IgM is the main type of RF, and this test kit mainly detects this type. Specification Test Item Sample Type Method Storage Condition RF S/P/WB Immunofluorescence Assay 4-30℃ Detection Range Test Time Cut-off Value Shelf Life 10.0-640.0 IU/mL 10 min 15.9 IU/mL 24 months Applicable Device Getein 1100 Immunofluorescence Quantitative Analyzer Getein 1160 Immunofluorescence Quantitative Analyzer Getein 1180 Immunofluorescence Quantitative Analyzer Getein 1200 Immunofluorescence Quantitative Analyzer Getein 1600 Immunofluorescence Quantitative Analyzer
Getein Cardiac Troponin I Fast Test Kit is used as an aid in the diagnosis of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome (ACS).