Contact Getein
Search
28 results found for "Analyzer"
  • Quantitative Immunoassay Analyzer
    Quantitative Immunoassay Analyzer
    FIA 8000 Quantitative lmmunoassay Analyzer
    Key Features User-friendly Interface  5.6 inch touch screen PC, LIS, HlS connectivity Simplified operation ltem auto-recognition Optional barcode scanner Reliable and advanced system  Up to 10000 data storage Multiple quality control 5 seconds/test for multiple samples  Application Scenarios ICU Emergency Room Clinic Test Menu Technical Specifications Methodology: Colloidal gold Result: Quantitative Dimensions: 250 mm (W) *250 mm (D) *120 mm (H)  Weight: 1.8 kg  Storage Capacity: 10000 data Sample Type: Serum, plasma, whole blood, urine, stool Language: English/Chinese/Spanish Screen: 5.6 inch touch screen Power Supply: 100-240V~50Hz/60Hz, 60VA Tempreture: -15~+40℃   Relative humidity: ≤93%  Air pressure: 50.0~106.0kpa  
  • Portable POC Quantitative Immunoassay Analyzer
    Portable POC Quantitative Immunoassay Analyzer
    FIA 8600 Quantitative lmmunoassay Analyzer
    Key Features Instant Testing  2-15 minutes/test 5 seconds/test for simple samples Optimized Operation One-step test Auto-recognition of test items Optional barcode scanner Use-friendly Design 7 inch touch screen Communication port USB / LAN Optional lithium battery Application Scenarios ICU Emergency Room Clinic Test Menu Technical Specifications Methodology: Colloidal gold Dimensions: 220 mm (D) *230 mm (W) *98 mm (H) Weight: 1.5 kg Sample Type: Serum, plasma, whole blood, urine, stool Storage Capacity: 10000 data Language: English/Chinese/Spanish Screen: 7 inch touch screen Printer: Internal thermal printer Certificate: CE, ISO  
  • Blood Testing Device
    Blood Testing Device
    BHA-3000 Automatic Hematology Analyzer
    Key Features No Residue No residue of hematology diluent or lysing reagent Cost-effective Small Blood Sample Venous blood: 6 μL Capillary blood (pre-dilution mode): 20 μL Intelligent Floating Threshold Accurate classification & reliable result Optimized Liquid System Limited failure rate & excellent maintainability Linear Fitting Break the 2 fL limit of detection of platelet volume Reportable Parameters WBC, NEU#, MXD#, LYM#, NEU%, MXD%, LYM%, RBC, HGB, MCV, RDW-CV, MCHC, MCH, RDW-SD, HCT, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 6 μL; capillary blood (pre-dilution): 20 μL Principles: Classic electrical impedance method, photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 425 mm x 446 mm (L x W x H)  Weight:16 kg Power Supply: 220V~ 50 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Blood Testing Device
    Blood Testing Device
    BHA-5000 Automatic Hematology Analyzer
    Key Features Digital Filtering Effectively remove interference Small Blood Sample Venous blood: 15 μL Capillary blood (pre-dilution mode): 20 μL Double Channels WBC double channels 2D classification, faster and more accurate 50μm Hole Accurate test of blood cells with 50 μm gem hole Coincidence Calibration Enhance analytical capabilities Reportable Parameters WBC, LYM#, NEU#, MON#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 471 mm x 446 mm (L x W x H)  Weight: 21 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • 5-part Veterinary Automatic Hematology Analyzer
    5-part Veterinary Automatic Hematology Analyzer
    BHA-5000 Vet Automatic Hematology Analyzer
    Key Features Humanization Venous blood sample volume: 15 uL Less pain during blood collection Sample type: venous blood/capillary blood (pre-dilution mode) to meet different needs Technology Innovation Intelligent scatter classification technology Curve-fitting&floating threshold technique Advanced methods Laser Scattering Method: Obtain information on the size and internal composition of WBC and classify them Digital Filtering: Effectively remove interference from impurity signals Optical Method for BASO: Avoid errors caused by the partial overlap of basophil and leukocyte High Efficiency and No Residue 60 T/H No hematology diluent or lysis reagent residues Blood Cell Overlap Correction Technology Make accurate judgments when cells overlap through the well Multi-Segment counting Better exclude biased results and improve test accuracy Smallest Gem Hole The industry's smallest gem hole of 50 um Display 10.4" capacitive touch screen, improve the sensitivity of touch operation Support operation with rubber gloves Species of Animals Dog, cat, pig, horse, sheep, rabbit, camel, one self-programmed animal Technical Specifications 23 Whole Blood Reportable:WBC、LYM%、LYM#、NEU%、NEU#、MON%、MON#、EOS%、EOS#、BAS%、BAS#、RBC、HGB、HCT、MCV、MCH、MCHC、RDW-SD、RDW-CV、PLT、PDW、MPV、PCT Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: Laser Scatter in Flow Cytometry,Classic Electrical Impedance Method,Mature Photoelectric Colorimetry Power Supply:220V±22~AC,50±1 Hz,Larger voltage range can be supported by transformers Sample Volume:Whole blood: 15μL; Diluted blood: 20μL Dimensions:328 mm (L) x 471 mm (W) x 446 mm (H)   Performance:Parameter Precision (CV%),WBC ≤4.0,RBC ≤2.0,HGB ≤2.0,PLT (10^3/μL) ≤8.0,MCV ≤3 Display:10.4 Inch capacitive touch screen Quality Control:L-J QC, X-B QC Weight:21 kg  
  • Integrated Immunofluorescence and Hematology Modular System
    Integrated Immunofluorescence and Hematology Modular System
    Metis 600 Modular System
    Key Features Maximizing the potential of the laboratory Metis 600 modular system provides suitable solutions for immunofluorescence and hematology testing in low volume laboratories Standardization Improve laboratory efficiency through the highest level of automation Reliability Maximize reliable results with industry-leading instrument accuracy and service Rapid Accelerate turnaround time for high-volume sample testing and achieve new levels of rapid service Capacity The combination of Immunofluorescence and Hematology methodologies allows for a more comprehensive test items to be offered Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications BHA-5100 Automatic Hematology Analyzer Dimensions: 67 cm x 70.5 cm x 57 cm Weight: 21 kg Methodology: Flow cytometry, impedance method, colorimetry Throughput: 60 T/H Test items: 25 reportable parameters Quality control method: L-J quality control, X-B quality control Storage capacity: > 100, 000 patient data Gem Hole: 50 μm Sample Volume: 15 μL Reagents: 1 diluent and 2 lysers   Getein 1200 Immunofluorescence Quantitative Analyzer Dimensions: 67.5 cm × 57 cm × 57.4 cm Weight: 43 kg Methodology: Quantitative immunofluorescence Sample Positions: 50, continuous sample loading Reagent Positions: 4 x 24/48 Throughput: 120 T/H Test items: 42 items in 11 fields Storage capacity: 100, 000 test results Storage capacity: 100, 000 test results Dry System: ADP aspiration, no liquid path Automation: Automatic sample loading, mixing and decapping    
  • Automatic 5-part Hematology Analyzer
    Automatic 5-part Hematology Analyzer
    BHA-5100 Automatic Hematology Analyzer
    Key Features Advanced Automatic Level Autorotating blood collection tubes for barcode scanning Automatic sample mixing technology Automatic puncture sampling Exceeding Detection Technology Digital filter and linear regression Floating threshold technology for cell differentiation Display Screen ≥10.4 inch LCD display screen Able to display data and diagrams simultaneously User Friendly Minimize manual operations Bidirectional connectivity of LIS and HIS Supports external devices such as printers, keyboards, mouse and more Emergency Sample Position Available   Reportable Parameters WBC, Lym#, Neu#, Mon#, Eos#, Bas#, Lym%, Mon%, Neu%, Eos%, Bas%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT,  P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 705 mm×670 mm×570 mm (L x W x H) Weight: 30 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Leading Metis 6000 Modular System Manufacturer
    Leading Metis 6000 Modular System Manufacturer
    Metis 6000 Modular System
    Key Features Automatic Automatic & Streamlined workflow to reduce workload Independent emergency track, striving for more treatment time Flexible Flexible expansion enables the combination and collaboration of 1-4 modules Optional choice for SHC 200 system (Centrifuge & Decapper) Compact Metis 6000 takes up only 2.6 m2 for two modules Only increasing 1.0 m2 by upgrading with SHC 200 system (Centrifuge & Decapper) Intelligent Optional SHC 200 pre-analytical module can realize Automatic tube decapping and cap disposal Automatic sample centrifugation Centrifugation time, speed and temperature can be set according to needs Application Scenarios Hospital Labs Diagnostic Centers Check-up Centers Test Menu Technical Specifications MAGICL 6200 Immunochemistry Module Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 400 T/H Fastest Time of First Result: 10 min Reaction Cup: Using mainstream circular reaction cup, up to 2000 pieces can be stored at a time Reagent Tray: 30 reagent positions with 2-8 ℃ internal air circulation refrigeration Dimensions:1100 mm(L)×930 mm(W)×1200 mm(H) CM-1000 Clinical Chemistry Module Throughput: Constant speed of 1000 T/H; optional ISE module: 400 T/H Simultaneously detected items: 61 Cuvettes: 270 quartz glass or plastic cuvettes (optical path: 5 mm)  Reagent Tray: 63 reagent positions for outer tray (20/70 mL) 40 reagent positions for inner tray (20/70 mL)  Dimensions: 1100 mm(L)×930 mm(W)×1200 mm(H)  
1 2 3 4

A total of 4 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service