Contact Getein
Search
7 results found for "Fully Automated Analyzer"
  • Blood Testing Device
    Blood Testing Device
    BHA-5000 Automatic Hematology Analyzer
    Key Features Digital Filtering Effectively remove interference Small Blood Sample Venous blood: 15 μL Capillary blood (pre-dilution mode): 20 μL Double Channels WBC double channels 2D classification, faster and more accurate 50μm Hole Accurate test of blood cells with 50 μm gem hole Coincidence Calibration Enhance analytical capabilities Reportable Parameters WBC, LYM#, NEU#, MON#, EOS#, BAS#, LYM%, MON%, NEU%, EOS%, BAS%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 328 mm x 471 mm x 446 mm (L x W x H)  Weight: 21 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Automatic 5-part Hematology Analyzer
    Automatic 5-part Hematology Analyzer
    BHA-5100 Automatic Hematology Analyzer
    Key Features Advanced Automatic Level Autorotating blood collection tubes for barcode scanning Automatic sample mixing technology Automatic puncture sampling Exceeding Detection Technology Digital filter and linear regression Floating threshold technology for cell differentiation Display Screen ≥10.4 inch LCD display screen Able to display data and diagrams simultaneously User Friendly Minimize manual operations Bidirectional connectivity of LIS and HIS Supports external devices such as printers, keyboards, mouse and more Emergency Sample Position Available   Reportable Parameters WBC, Lym#, Neu#, Mon#, Eos#, Bas#, Lym%, Mon%, Neu%, Eos%, Bas%,  RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT,  P-LCR, P-LCC Technical Specifications Sample Mode: Whole blood (venous/capillary), pre-dilution Sample Volume: Venous blood: 15 μL; capillary blood (pre-dilution): 20 μL Principles: White blood cell: laser scattering + sheath flow technology; red blood cell/platelet: impedance method; hemoglobin: photoelectric colorimetry Screen Type: 10.4 inch resistive screen Data Storage: 100000 Dimensions: 705 mm×670 mm×570 mm (L x W x H) Weight: 30 kg Power Supply: 100-240 V~ 50/60 Hz Operating Conditions: 18~30℃, ≤80%; relative humidity: 75 kPa~106 kPa QC Methods: L-J QC, X-B QC  
  • Automatic Clinical Chemistry Analyzer
    Automatic Clinical Chemistry Analyzer
    BBA-300 Automatic Clinical Chemistry Analyzer
    Key Features Highly-efficient and Convenient Test  Constant throughput: 300 T/H Emergency samples in test priority at any time 45 samples positions, 2 emergency sample positions, 90 reagent positions Multifunctional and Precise Sample Probe Highly-polished probe Automatic inside and outside probe washing, reducing cross contamination Highly sensitive liquid level detection sensor, actively monitoring reagent volume Reaction Unit 120 cuvettes, can be replaced separately 5-step cuvette wash station, thorough cleaning Stirring Unit  Independent stirring paddle Imported Teflon coating technology, effectively preventing cross contamination Application Scenarios Hospital Labs Diagnostic Centers Academic Research Institutes Test Menu Technical Specifications Test Principles: Turbidimetry, colorimetry Test Methods: Rate method, end point method, fixed-time method Dimensions:1060 mm (L) * 660 mm (W) * 1230 mm (H) Gross Weight: 140 kg Sample Positions: 45 positions, 2 emergency positions  Reagent Positions: 90 positions Sample Types: Blood, urine, hydrothorax,  cerebrospinal liquid fluid Application Scenarios: Hospital labs, diagnostic centers, academic research institutes   Water Consumption: No more than 20 L purified water per hour Minimum reaction volume: 150μL Minimum sampling volume: 2μL  
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 6000i Chemiluminescence Immunoassay Analyzer
    Key Features Compact Design Bench top design Relatively lighter weight: 80 kg High Efficiency Throughput: up to 200 T/HFastest time for the first result: 12 min Dual-Tray Consumable Design 2 independent consumable trays, support replacement without pause 140 reaction cups per tray Smooth Reagent Management 24 reagent positions, support online loading PE film puncture technology, preventing reagents from evaporationEquipped with RFID, automatic identification of reagent information Application Scenarios Medical Laboratories Clinics Health Check-up Center Test Menu Technical Specifications Test Principle: Acridinium ester direct chemiluminescence Throughput: Up to 200 T/H Fastest Time for the First Result: 12 min Reagent Positions: 24 Sample Positions: 50 Sample Type: Serum, plasma, urine, fingertip blood Application Scenarios: Laboratory, Clinics, Emergency, ICU, Wards Sampling Method: Steel needle STAT: Support STAT mode Sensing Functions: Liquid level detection, residual monitoring of reagent and sample, anti-collision Reaction Cups: 2 individuals consumble trays with 140 reaction cups each Reaction Temperature: 37℃±0.5℃ Magnetic Seperation & Washing: 3-step magnetic separation and 3-step washing Dimensions: 685 mm(L)*690 mm(W)*660 mm(H) Weight: 80 kg
  • Chemiluminescence Immunoassay Analyzer
    Chemiluminescence Immunoassay Analyzer
    MAGICL 6200 Chemiluminescence Immunoassay Analyzer
    Key Features Fast and accurate tests with small footprint High throughput at 400 T/H can satisfy needs from different hospitals and laboratories Compact footprint, maximizing space utilization efficiency Flexible expansion for modular system Support expansion of centrifuge and decapper module / analysis modules Flexible combination of 4 analysis modules at most, fulfilling requirements from multiple laboratories High automation level Automatic sample loading and scanning, automatic weight balanced in centrifuge module without manual operation Intelligent software system Support auto-dilution and auto-retests Monitor real-time instrument status, testing status, reagent reserve and consumables status Application Scenarios Medical Laboratories Indipendent Clinical Laboratory Health Check-up Center Test Menu Technical Specifications Methodology: Acridinium ester direct chemiluminescence Analysis methods: Sandwich method, competition method Test Items: 118 items. Up to 85 items tested simultaneously Test Speed: Up to 400 T/H Fastest Time for the First Result:12 min Sample Volume: 10 uL~150 uL (1 uL increment) Sample Loading:Sample loading by tracks, sample/return/emergency track Maximum loading capacity: 190 sample positions Reagent Volume: 10 uL~150 uL (0.1 uL increment) Reagent Tray: 30 reagent positions Cooling function: internal air circulation cooling with a range of 4~8℃ Cuvettes:Using mainstream circular cuvettes, up to 2000 can be stored in hopper at a time Incubation Temperature: 37±0.2°C Preheating Time:<15 min Magnetic Separator Cleaning: Four-step magnetic separation, four-step cleaning Dimensions: 1100 mm (L) x 930 mm (W) x 1200 mm (H)  
  • Immunofluorescence Quantitative Analyzer
    Immunofluorescence Quantitative Analyzer
    Getein 1600 Immunofluorescence Quantitative Analyzer
    Key Features Instant Results Get results in 3-15 minutes Most Advanced  The Getein1600 Fully Automated Fluorescence Immunoassay Analyzer is a pioneering product in the international POCT (Point-of-Care Testing) field, representing a breakthrough in high-end automated technology for domestic POCT products. More Convenient Fully automated, it can complete the entire process of quality control, sample aspiration, dilution, mixing, measurement, calculation, and report printing. It supports automatic program upgrades and integration with LIS and HIS systems. More Functional Features random sample insertion, allowing for immediate testing of emergency samples at any time. More Efficient Requires only a minimum of 10 µL sample volume for detection and supports testing of whole blood, serum, plasma, and urine samples. More Aesthetic Equipped with an Android operating system and a 10.1-inch LCD touchscreen display, it offers easy operation, a modular structure, and software for convenient upgrades and maintenance. High Throughput Capable of simultaneously testing three different parameters from the same sample, it can process up to 48 samples at once, with a throughput of up to 150 samples per hour. The average detection time is less than 30 seconds per sample. Application Scenarios ICU Laboratory Emergency Clinic     Test Menu Technical Specifications Dimensions: 639mm(W)×562mm(D)×728mm(H) Weight: 45 kg Sample Positions: 48 Reagent Positions: 4*24/48 Printer: Built-in Thermal Printer, support for external printer Display: 10.1'' LCD touch screen  Connectivity: Ethernet port for LIS/HIS COM port for PC Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Cases Storage: Over 500,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV  
  • Fully Automated Immunofluorescence Quantitative Analyzer
    Fully Automated Immunofluorescence Quantitative Analyzer
    Getein 1200 Immunofluorescence Quantitative Analyzer
    Key Features Instant Results Get results in 3-15 minutes High Throughput Capable of processing multiple samples simultaneously, ensuring fast turnaround times Accuracy and Precision Utilizes advanced immunofluorescence technology to deliver highly accurate and reproducible results User-Friendly Interface  Equipped with a touch-screen interface for easy operation and minimal training requirements Versatile Applications Suitable for a wide range of tests, including cardiac markers, inflammation markers, fertility tests, and more Compact Design Space-saving design that fits well in various laboratory settings without compromising performance Application Scenarios ICU Laboratory Emergency Clinic     Test Menu Technical Specifications Dimensions: 675 mm(W)×570 mm(D)×574 mm(H) Weight: 43 kg Sample Positions: 50 Reagent Positions: 4*24/48 Printer: Built-in Thermal Printer, support for external printer Display: 12.1'' LCD touch screen  Connectivity: Bidirectional LiS/HS connectivity Calibration: RFID Card Calibration Sample Type: serum, plasma, whole blood, capillary blood, urine Sample Volume: 10 ~ 200 μL depending on the assay Language: English/Spanish/Chinese Cases Storage: Over 100,000 test cases Repeatability: CV ≤ 2% within range [100, 15000] mV; CV ≤ 10% within range [0, 100) mV

A total of 1 pages

Categories
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Leave A Message

Leave A Message
Leave your message here should you be interested by any of our product offerings, we will get back to you in minimal delay.

Home

Products

contact

service